Device Configuration

Your ValueCAN4-4 ships from the factory with default settings. Default settings to consider are:

  • Four CAN FD networks enabled
  • Classical CAN mode set to 500 Kbps
  • CAN FD mode set to 2Mbps
  • CAN Termination disabled
  • Normal communication mode (allows transmit, receive and acknowledges CAN/CAN FD frames)

Other defaults are indicated later in this section.

Note that the settings needed for your application may not match the default settings. You can customize the settings to your exact needs. This section covers how to manage and fine-tune your ValueCAN4-4.

Your ValueCAN4-2EL ships from the factory with default settings. Default settings to consider are:

  • Both CAN FD networks enabled
  • Classical CAN mode set to 500 Kbps
  • CAN FD mode set to 2Mbps
  • LIN network enabled
  • 1 DoIP / XCP / 100BASE-TX 10/100 Ethernet PHY with low power mode disabled
  • CAN Termination disabled
  • Normal communication mode (allows transmit, receive and acknowledges CAN/CAN FD frames)

Other defaults are indicated later in this section.

Note that the settings needed for your application may not match the default settings. You can customize the settings to your exact needs. This section covers how to manage and fine-tune your ValueCAN4-EL.

5. The neoVI Explorer Configuration Utility

5.1. Starting and Using neoVI Explorer

This section will describe general features and the basics of using neoVI Explorer. It is the utility is used to connect to, manage and configure all of Intrepid Control Systems hardware. It is an integral part of Vehicle Spy, but for those not using Vehicle Spy software, it is also available as a stand alone application in the free ICS Hardware Installation kit

5.1.1. Starting neoVI Explorer from within Vehicle Spy

There are several ways to open neoVI Explorer from within VSpy. These are probably the two easiest, since they are accessible at all times:

  • Menu Item: Click the Setup menu and then select Hardware.
  • Hardware Setup Button: Click the button located in the main Vehicle Spy toolbar just under its menu (Figure below).
_images/Go_neoVI_Explorer.png

Note

neoVI Explorer cannot be launched when Vehicle Spy is online (even if in simulation mode). Attempting to do so, VSpy will display a prompt to either go offline and launch neoVI Explorer, or remain online and return to Vehicle Spy.

5.1.2. Starting neoVI Explorer as a Standalone Program

It is also possible to launch neoVI Explorer directly without opening Vehicle Spy. Open the Start Menu, navigate to the IntrepidCS folder, then under the Vehicle Spy 3 sub-folder, select neoVI Explorer (Figure below).

_images/neoVI_Exp_Standalone.png

5.1.3. Starting neoVI Explorer as a Standalone Program

If the ICS Hardware Installation kit has been installed instead of Vehicle Spy, neoVI Explorer can be run from the Start Menu using the same basic process as described above. The only difference is the name of the sub-folder. The location of neoVI Explorer within the folder hierarchy can be seen in the figure below.

_images/neoVI_Exp_API.png

5.2. Interfacing with a device

5.2.1. Connecting to a device

When neoVI Explorer loads, it will start up with the first hardware device it can find selected in the menu pane on the left. Any connected devices should be listed here, along with its serial number. If a particular device is connected, but not seen among a list of other Intrepid devices, be sure to scroll down to look for it. If it is still not visible, this means its drivers have not been installed correctly, it is not powered properly, or there is a problem with the connection to the host computer.

To manage a device, click on its entry in the navigation pane (if it is not already highlighted) and then press the Connect button. After successfully connecting to the device, a “thumbs up” icon will be displayed next to the device’s name, and checkmarks will appear next to currently-enabled networks in the explorer area on the left. A message in the message box on the right will also read “<Your Device and Serial Number> settings have been read”. This indicates that neoVI Explorer has loaded the current settings from the unit.

The screen as a whole should appear similar to the screen shown below (but note that the device and version number shown below may be different).

_images/nVE_Screen.png

Note that this screen varies in content between Intrepid devices.

Searching for Devices

After attaching new hardware to a PC and starting neoVI Explorer, press the Search For Devices button at the bottom left of the dialog box to prompt the program to scan for new hardware to be managed.

Note

It is possible to click on various parameter groups at any time, but they will not show valid data until connected to the device. Remember also to connect to the device before making changes; Any changes made in neoVI Explorer with no device connected will be overwritten by a devices settings when it is connected.

5.2.2. Device Configuration

Writing and Reloading Settings

To avoid potential problems, neoVI Explorer will not save any changes to device parameters until instructed it to do so. This is done by pressing the Write Settings button, which will update the parameters within the firmware in the device. If unwanted changes were made, pressing the Read Settings button will reload the settings stored in the device, wiping out any modifications made in neoVI Explorer that had not yet been saved.

Reloading Device Defaults

To return all settings to factory defaults, press the Load Default Settings button. Note that pressing this button actually writes the defaults to the device first, and then reloads them automatically, so it is not necessary to also press Write Settings. The message area will display that defaults have been sent to the device and then read from it.

Disconnecting from the device

Press the Disconnect button to tell neoVI Explorer disconnect the device. This step is actually optional, because neoVI Explorer will disconnect from any connected devices when the program is closed.

Exiting neoVI Explorer

Like any Windows program, neoVI Explorer can be closed by clicking the “X” in the top right corner, or pressing the Alt+F4 key combination.

5.3. System Settings and Firmware Updates

The top two entries in the explorer window on the left side of neoVI Explorer contain system- wide settings that apply to all hardware devices, and information related to firmware updates.

5.3.1. System Settings

In the top branch of the tree in the left pane of neoVI Explorer there are several settings that can be enabled or disabled:

_images/nVE_System_Settings.png
  • Enable Server: Turns on the neoVI Server feature, a background program that allows the hardware to be used by multiple applications at the same time.
  • Enable Low Latency: This is an advanced setting for applications where fast response is needed after transmission.
  • Enable Auto Update: When enabled, both neoVI Explorer and Vehicle Spy will automatically update firmware. If this box is not checked, firmware must be updated manually. (See below for details.)
  • Network Adapter Server: This is a feature that is used with Intrepid products having Ethernet ports. (It may not apply to your device.) With This feature enabled, the Ethernet ports on Intrepid hardware will enumerate as network interfaces in the operating system of the host computer. This server can be started and stopped in this window. There is also a checkbox to configure the server to start after booting of the computer.

5.3.2. Available Firmware

This is an informational page that shows which firmware versions are available in this version of neoVI Explorer for various Intrepid products. Note that some devices have multiple firmware programs that control different aspects of their operation;

5.3.3. Automatic and Manual Firmware Updates

Warning

While a device may appear to operate with incompatible firmware, proper and reliable operation cannot be guaranteed unless the version of firmware matches what is listed in Vehicle Spy

Firmware is essentially software that runs inside hardware and is required to enable the many capabilities of a device. New versions of firmware are created regularly by Intrepid’s engineers to implement new features and correct problems that have been identified.

Enable Auto Update is on by default and is recommended for most users. Each time a device connects neoVI Explorer or Vehicle Spy, the firmware will be checked, and if a newer version is available, the device will immediately be updated. If automatic updates is not enabled, it can be updated manually as needed. When new firmware is available, a red notification will be displayed on the initial connection screen, as shown below. Simply press the Manual Reflash button to update the firmware.

_images/Automatic-and-Manual-Firmware-Updates.png

Note that this screen varies in content between Intrepid devices.

5.3.4. The Firmware Update Process

During the firmware update process, the device will be placed into bootloader mode, indicated by all LEDs on the top label flashing synchronously. Normal LED flash patterns will resume when the update is complete and the device reboots. The progress of the firmware update operation is displayed in a dialog box as shown below. A message box on the right side of neoVI Explorer will also be displayed as the firmware program is sent to the device. When the process is complete the dialog box will disappear and another message will appear in neoVI Explorer to confirm that the update has finished. If any error messages are displayed or any other problems experienced updating the device’s firmware, please contact Customer Support for assistance.

_images/Reflash_Status.png

Warning

Please take heed of the warning on the firmware update dialog box: leave the device connected and powered on for the entire firmware update process to avoid possible problems with the device.

5.4. General Settings and Product Details

These two areas of the device’s parameter setup provide information about the device and can be used to perform a few basic maintenance tasks.

5.4.1. General Settings

After connecting to the device, basic information about it will be displayed in the right-hand pane of the window:

  • The device’s serial number.
  • The firmware versions currently in the device, and an indication if new firmware is available.
  • A message showing that the hardware license for the device was recognized.
  • A current readout of the device’s real-time clock.
_images/General_Settings.png

This information can be displayed again at any time by clicking the device’s name in the explorer navigation window, or the General Settings entry immediately below it.

The version(s) of the firmware for the device will be shown in black if it matches the firmware version within neoVI Explorer. If not, the current version and the newest available version will be shown in red to highlight that an update is available. (See the previous section for more about the update process.)

There are three buttons on this screen.

  1. Manual Reflash (described in the previous section)
  2. Read RTC button will reload the device’s internal time clock
  3. Synchronize RTC will set the device’s clock to the same value as that of the PC.

5.4.2. Product Details

This is an informational area that provides technical data on the devices’s hardware and internal setup. This is generally only needed this if requested by Intrepid in order to facilitate support or troubleshooting. The Copy To Clipboard button can be used to copy all of the information to the Windows Clipboard to be pasted into an email or file.

5.5. CAN Network Settings

5.5.1. CAN Networks

This area of neoVI Explorer is used to enable, disable and configure the High Speed CAN channels. Each channel has an entry under the “CAN” group (which cannot be clicked itself). The current status of each channel is shown next to its name; a green checkmark indicates that the channel is enabled, while a red X means it is disabled. The figure below shows an example of the CAN channels area, with HS CAN enabled and HS CAN2 disabled.

_images/CAN_Tree.png

All of the CAN channels have the same parameters, which can be configured using the controls in the right-hand pane; the default settings are shown below.

_images/CAN_Settings.png

Enabled: Place a checkmark in this box to enable the channel, or clear the checkmark to disable it. When disabled, all of the other parameter controls are disabled (grayed out).

Specify by Baud: This is a master control that determines whether the operation of the channel is controlled by a numeric baud rate, or is calculated from lower-level timing parameters. When checked, the Baud Rate and CAN FD Baud Rate drop-down boxes are enabled and the various TQ, Sync and BRP-1 entries are disabled. When unchecked, this is reversed. Specifying by baud rate is the default, and is recommended except for advanced users with special requirements.

Baud Rate: When Specify by Baud is selected, choose a baud rate for the channel from the drop-down box below. The default value is 500000.

CAN Timing Settings: When Specify by Baud is deselected, the operation of the CAN channel is based on these five settings: TQ SEG1, TQ SEG2, TQ Prop, Sync, BRP-1. These settings are for advanced users and normally should be left at their default values.

CAN FD Baud Rate: When Specify by Baud is selected, choose a baud rate for the data phase of CAN FD messages. The default value is 2000000.

CAN FD Timing Settings: When Specify by Baud is deselected, use these settings (TQ SEG1, TQ SEG2, TQ Prop, Sync, BRP-1) for the data phase of CAN FD messages. These parameters are for advanced users and normally should be left at their default values.

Mode: The operating mode of the channel; choose from one of these four options:

  • Normal: Normal operation (default).
  • Disable: Channel is disabled.
  • Listen Only: This channel only receives messages, with no transmissions, and also no error frames generated nor acknowledgments sent.

Bit Rate Calculator: Press this button to launch the Intrepid Bit Timing Calculator.

5.5.2. ISO15765-2:

This page contains one setting: IFS Shift Register (shown below). Changing this from its default value of 0 causes time to be added to the Inner Frame Spacing of USDT frames transmitted by CoreMini scripts running in the FIRE 2. The number entered is multiplied by 6.4 µs to determine the time offset. The allowed range is -1563 to 1563.

_images/ISO15765.png

5.6. LIN Network Settings

This section the device’s explorer tree allows enabling, disabling and configuring its LIN channels. Each channel has an entry under the “LIN” group (seen below). As with the CAN channels, a green checkmark indicates that a particular channel is enabled, while a red X means it is disabled.

_images/LIN_Tree.png

All of these channels have the same parameters, which can be seen below. In this image we have selected the Advanced Options checkbox to display its options (described below).

_images/LIN_Settings.png

<div style=”page-break-after: always;”></div>

Enabled: Place a checkmark in this box to enable the channel, or clear the checkmark to disable it. When disabled, all of the other parameter controls are disabled (grayed out).

Baud Rate: Select a baud rate for the channel; the default is 10417.

Mode: This option is currently not used and should be left at the default of “Normal Mode”.

Master Resistor On: Enable this option for the device to act as the master on the specified LIN bus.

Advanced Options: Click this checkbox to reveal two additional options:

  • Master Slave Interval: The time between the master ID and the first slave byte, in bits (default 0).
  • Verbose Error Reporting: When checked, break errors and other error messages from the LIN driver are displayed.