Message Capture Method: Stop Options: Pre/Post Collection

When using the Message Capture method for Standalone Logging within VehicleScape DAQ, selecting Start using trigger expression for the Start Option provides two Stop Options: Pre/Post Collection (described here) and One-shot Report.

Figure 1 shows the default appearance of the Stop subsection of the Standalone Logging tab when Pre/Post Collection is selected. The settings and prompts will change slightly depending on the parameters selected.


Figure 1: The Pre/Post Collection Stop option block.

Stop on expression

The Stop on expression box controls the overall behavior of this stop option. Check the box to have logging stop when the expression is true, then use the button to select the expression using the Expression Editor.

Checking the box enables these optional features:

Note: Checking the Stop on expression box changes some Pre-Trigger and Post-Trigger settings (see below) and removes the Stop option from Restart Options.

Pre-Trigger and Post-Trigger Settings

The options in this area control how much data is collected before and after the defined trigger expression. There are two main choices:

Card Size and # of Trigger Events

A drop-down box called Card Size also appears in this area. Select the size of the SD card being used in the standalone logger, and Vehicle Spy will estimate the maximum number of trigger events that it can hold based on your chosen parameters.

This option is not relevant when the Stop on expression feature is used, so it doesn't appear if that box is checked.