CAN Networks - neoVI
Main

Applies to
neoVI Blue, neoVI Red, neoVI FIRE, neoVI Yellow, and ValueCAN

The CAN controllers used in neoVI and ValueCAN support a few different CAN modes (figure 1). A summary of the modes are given below in table 1.

Table 1 - CAN Controller Device Modes

Mode Description
Normal Mode Normal CAN Communications.
Listen Only CAN Rx only with no error frames generated or acknowledges
Loopback (Blue Only) No Network operation. All messages transmitted are seen as received messages.
Listen All (Except Blue) No Network operation. All messages transmitted are seen as received messages.  All messages are received regardless of errors in frame
Disable No Network operation.

 


Figure 1 - You can select the CAN controller mode in the neoVI Explorer.

 