8. Errata

Errata ID

RM3-1

Date

12/15/2022

HW Version

Rev 1

FW Version

NA

Description

Full validation of 10G performance has not been completed.

Impact/Workaround

RAD-Moon3 may not meet all performance criteria related to BER and frame loss at 10 Gbps.

Resolution

Hardware Rev 3.2 (All products with serial number > R13651)

Improvements in SQI, Return Loss, and overall 10G performance and stability.

Status

Closed

Last Revised

11/25/2024


Errata ID

RM3-2

Date

12/15/2022

HW Version

Rev 1

FW Version

NA

Description

Inaccurate minimum operating voltage on bottom label.

Impact/Workaround

The minimum operating voltage of RAD-Moon3 is 6V. Bottom label was printed before production design was finalized and references 5V as the minimum operating voltage. There is no risk of damage to the device operating at a voltage less than 6V, but it may not operate reliably.

Resolution

Label will be revised.

Status

Closed

Last Revised

12/15/2022


Errata ID

RM3-3

Date

12/17/2024

HW Version

NA

FW Version

NA

Description

TC10 functions not implemented.

Impact/Workaround

The TC10 API was not available from the PHY supplier at start of production.

Resolution

TC10 functions will be implemented shortly after receipt of TC10 API from PHY supplier.

Status

Open

Last Revised

12/17/2024