Columns in the table can be filtered, reorganized, added, and hidden.
These table features are common across all tabs in this area.
To add items to the table you can:
Default Columns |
Description |
Name |
Unique identifier of the Characteristic.
Here are the main requirements for this field:
Max overall length = 1024 characters.
Max partial string length = 128 characters.
Allowed characters: A - Z, a - z, 0 - 9, underscores, periods, and brackets [ ].
Must NOT contain spaces.
First character must be a letter or an underscore.
Any brackets must occur in pairs at the end of a partial string.
Any bracket pairs must surround a number or string.
Name is case sensitive. (i.e. "b" and "B" are considered unique)
If in doubt about valid names, please refer to the ASAM specifications. |
Type |
The ASAP2 Editor supports these 3 types of Characteristics:
Value - a single value with no axis.
Curve - an array of values with 1 axis.
Map - a table of values with 2 axes. |
Address |
Memory Address of the Characteristic. |
Deposit |
Specifies the data structure.
The default layout will update depending upon the Data Type field.
The dropdown selections come from the Record Layouts tab.
The Data Type over on the Record Layout tab must match the Data Type field on this dialog. |
Conversion |
Applies the selected Conversion Method to the value.
The dropdown selections come from the Conversion Methods tab. |
LowerLimit |
Lower limit of plausible range of values.
A default limit is determined mathematically by the Data Type selection.
Note: The default limit is reapplied each time the Data Type is changed. |
UpperLimit |
Upper limit of plausible range of values.
A default limit is determined mathematically by the Data Type selection.
Note: The default limit is reapplied each time the Data Type is changed. |
BitMask |
Masks out single bits of the value to be processed.
0xFF = no mask for that byte.
This property defaults to no masking with the number of 0xFF's determined by the Data Type selection.
Note: The default mask is reapplied each time the Data Type is changed.
|
MaxDiff |
Maximum adjustment allowed to the Characteristic.
Entered as an absolute value, not as a percentage. |
Format |
Display formatting applied to numerical values.
If specified, this Format property overrides any formatting in the Conversion Method property.
The syntax for this field is: %Length.Layout
Length = overall length
Layout = number of decimal places |
In Group |
The Group this item is in. |
Data Type |
Determines the number of bytes dedicated to the value and how those bytes are interpreted.
This property should be chosen early because it applies defaults to the Bit Mask, Lower/Upper Limit, and Extended Lower/Upper Limit properties.
UBYTE - 1 byte unsigned integer
SBYTE - 1 byte signed integer
UWORD - 2 byte unsigned integer
SWORD - 2 byte signed integer
ULONG - 4 byte unsigned integer
SLONG - 4 byte signed integer
FLOAT32_IEEE - 4 byte (32 bit) floating point IEEE format
FLOAT64_IEEE - 8 byte (64 bit) floating point IEEE format
FLOAT32_TASKING - 4 byte (32 bit) floating point tasking format
|
|
Hidden Columns |
Description |
CalibrationAccess |
There are 4 types of access for MCD systems (test tools):
CALIBRATION - read and write allowed.
NO_CALIBRATION - read only.
NOT_IN_MCD_SYSTEM - read and write not allowed, for internal ECU use only.
OFFLINE_CALIBRATION - read allowed, write only allowed offline. |
DisplayIdentifier |
An alternative display name that is usually much shorter than the Name property.
Can be useful for devices with small display areas. |
Extended Lower Limit |
Extends the lower limit of plausible values.
Can be useful for generating warnings when the Lower Limit is exceeded.
A default limit is determined mathematically by the Data Type selection.
Note: The default limit is reapplied each time the Data Type is changed. |
Extended Upper Limit |
Extends the upper limit of plausible values.
Can be useful for generating warnings when the Upper Limit is exceeded.
A default limit is determined mathematically by the Data Type selection.
Note: The default limit is reapplied each time the Data Type is changed. |
KeyName |
Name from a map file symbol dropped into the A2L item area. |
LongIdentifier |
Comment or description. |
Manual Flag |