Axis Pts Tab

Axis Pts define axes that are shared across multiple Characteristic curves or maps.  These axes have a Characteristic Axis Type = COM_AXIS.

The Axis Pts tab has a table to display all A2L file Axis Pt items and their properties.  Each row (below the 1st filtering row) defines an Axis and each column is a property.  The default column configuration is shown in Figure 1.


Figure 1: The Axis Pts tab in the A2L file item area.

Columns in the table can be filtered, reorganized, added, and hidden.  These table features are common across all tabs in this area.

To add items to the table you can:

To edit items already in the table with the Edit Axis Pts dialog you can: Refer to Table 1 below for a description of each column on the Axis Pts tab.

Table 1: Column Descriptions for the Axis Pts Tab

Default Columns Description
Name Unique identifier of the Axis Pts.

Here are the main requirements for this field:
  • Max overall length = 1024 characters.
  • Max partial string length = 128 characters.
  • Allowed characters: A - Z, a - z, 0 - 9, underscores, periods, and brackets [ ].
  • Must NOT contain spaces.
  • First character must be a letter or an underscore.
  • Any brackets must occur in pairs at the end of a partial string.
  • Any bracket pairs must surround a number or string.
  • Name is case sensitive. (i.e. "b" and "B" are considered unique)


  • If in doubt about valid names, please refer to the ASAM specifications.
    InputQuantity References a Measurement to be used as a working point on the axis to track along the curve or map.  The dropdown selections come from the Measurements tab.
    Address Memory Address of the Axis Pts in the ECU.
    Deposit Specifies the data structure.  The default layout will update depending upon the Data Type field.  The dropdown selections come from the Record Layouts tab.  The Data Type over on the Record Layout tab must match the Data Type field on this dialog.
    Conversion Applies the selected Conversion Method to the value.  The dropdown selections come from the Conversion Methods tab.
    MaxAxisPoints Maximum number of axis points.
    LowerLimit Lower limit of plausible range of values.  A default limit is determined mathematically by the Data Type selection.

    Note: The default limit is reapplied each time the Data Type is changed.
    UpperLimit Upper limit of plausible range of values.  A default limit is determined mathematically by the Data Type selection.

    Note: The default limit is reapplied each time the Data Type is changed.
    MaxDiff Maximum adjustment allowed to an axis point.  Entered as an absolute value, not as a percentage.
    Format Display formatting applied to numerical values.  If specified, this Format property overrides any formatting in the Conversion Method property.

    The syntax for this field is: %Length.Layout
  • Length = overall length
  • Layout = number of decimal places
  • Hidden Columns Description
    CalibrationAccess There are 4 types of access for MCD systems or test tools:
  • CALIBRATION - read and write allowed.
  • NO_CALIBRATION - read only.
  • NOT_IN_MCD_SYSTEM - read and write not allowed, for internal ECU use only.
  • OFFLINE_CALIBRATION - read allowed, write only allowed offline.
  • DataType Determines the number of bytes dedicated to the value and how those bytes are interpreted.  This property should be chosen early because it applies defaults to the Lower/Upper Limit and Extended Lower/Upper Limit properties.

  • UBYTE - 1 byte unsigned integer
  • SBYTE - 1 byte signed integer
  • UWORD - 2 byte unsigned integer
  • SWORD - 2 byte signed integer
  • ULONG - 4 byte unsigned integer
  • SLONG - 4 byte signed integer
  • FLOAT32_IEEE - 4 byte (32 bit) floating point IEEE format
  • FLOAT64_IEEE - 8 byte (64 bit) floating point IEEE format
  • FLOAT32_TASKING - 4 byte (32 bit) floating point tasking format
  • DisplayIdentifier An alternative display name that is usually much shorter than the Name property.  Can be useful for devices with small display areas.
    ExtendedLowerLimit Extends the lower limit of plausible values.  Can be useful for generating warnings when the Lower Limit is exceeded.  A default limit is determined mathematically by the Data Type selection.

    Note: The default limit is reapplied each time the Data Type is changed.
    ExtendedUpperLimit Extends the upper limit of plausible values.  Can be useful for generating warnings when the Upper Limit is exceeded.  A default limit is determined mathematically by the Data Type selection.

    Note: The default limit is reapplied each time the Data Type is changed.
    KeyName Name from a map file symbol dropped into the A2L item area.
    LongIdentifier Comment or description.
    Manual Flag Manual flag setting from the Address tab on the Axis Pts' edit dialog.


      ASAP2 Editor Documentation - (C) Copyright 2021 Intrepid Control Systems, Inc.