Single Wire CAN - neoVI
Main

Applies to
neoVI Blue, neoVI Red, and neoVI FIRE

The neoVI single wire CAN channel is a GMW3089/ SAE J2411 (Silicon: TLE6255) CAN channel. Like all CAN Channels, this channel has programmable baud rate/bit timing and CAN device mode

The single wire CAN physical layer contains three operational modes. They are the following 1) normal communication mode, 2) high-voltage wake up mode, and 3) high-speed mode. The default baud rate is used for normal and high-voltage modes. For the high-speed mode, you need to specify an additional baud rate (this is done on the High Speed Mode panel).

neoVI provides two modes for the high speed setting, one is used for monitoring high speed and the other is to operate as a test tool. GMW3089 requires a test tool to switch in a specified test tool resistor when transmitting in high speed mode.

 neoVI   Documentation - (C) Copyright 2000-2020 Intrepid Control Systems, Inc.

Last Update: Thursday, July 09, 2009