Standalone Logging Collection Configuration - Pre/Post Collection |
In VehicleScape DAQ the Standalone Logging of a Messages collection
has a Collection Configuration setup area that changes appearance based upon what Collection Start Option is selected.
Table 1: Standalone Logging Collection Configuration - Pre/Post Collection Options
The Collection Configuration in Figure 1 is displayed if:
Collection Start Option = Using Trigger and Pre/Post Collection is selected.
Table 1 describes each setting in Figure 1 and some other settings that affect all collections.
Pre/Post Collection Setting
Description
Pre/Post Collection
For this collection, log data before and after the Collection Start trigger.
The capture window can be defined using an expression, a length of time, or a number of messages.
One-shot Report
For this collection, log a snapshot of data values after a Collection Start triggered chosen delay time.
Click the link to see further details.
Stop on expression
For this collection, stop logging when the expression is true.
"changing" checkbox
For this collection, stop logging when the expression changes from its current value.
Timeout sec
For this collection, stop logging when the expression is true/changes value OR after a timeout period in seconds.
This timeout is disabled if set = 0 and logging will stop based only upon the expression logic.
Card Size
SD card memory size in the ICS hardware that will run the Standalone Logging script.
By time
For this collection, use time to define the pre/post capture window.
Time Before/After Trigger
For this collection, save a log file that starts/stops at the chosen times around the Collection Start trigger.
By number of messages
For this collection, use message count to define the pre/post capture window.
Messages Before/After Trigger
For this collection, save a log file that starts/stops at the chosen message counts around the Collection Start trigger.
Collection / Log File Name
The name of this collection and the root name of all log files it creates.
The following settings affect ALL Standalone Logging collections
Reporting Options
Options for physical logger feedback and Live Data reporting to a Wireless NeoVI website.
Power Management
Logger sleep and wakeup selections are made here.
Generate
Generates the final script and opens a dialog to send it to ICS hardware that supports standalone logging.

Figure 1: The Collection Configuration if Collection Start = Using Trigger and Pre/Post is selected.
Last Update: Friday, May 3, 2013