Standalone Logging Collection Configuration - One Shot Report |
In VehicleScape DAQ the Standalone Logging of a Messages or Bus Query collection
has a Collection Configuration setup area that changes appearance based upon what Collection Start Option is selected.
Table 1: Standalone Logging Collection Configuration - One Shot Report Setting
The Collection Configuration in Figure 1 is displayed if:
Collection Start Option = Using Trigger and One-shot Report is selected.
Table 1 describes each setting in Figure 1 and some other settings that affect all collections.
One Shot Report Option
Description
Pre/Post Collection
For this collection, log data before and after the Collection Start trigger.
The capture window can be defined using an expression, a length of time, or a number of messages.
Click the link to see further details.
One-shot Report
For this collection, log a snapshot of data values after the Collection Start trigger then stop logging.
After trigger delay
For this collection, wait for a delay time (in seconds) after the Collection Start trigger then log a snapshot of data values and stop logging.
If the trigger delay = 0 then the One Shot Report will occur immediately.
Collection / Log File Name
The name of this collection and the root name of all log files it creates.
The following settings affect ALL Standalone Logging collections
Reporting Options
Options for physical logger feedback and Live Data reporting to a Wireless NeoVI website.
Power Management
Logger sleep and wakeup selections are made here.
Generate
Generates the final script and opens a dialog to send it to ICS hardware that supports standalone logging.

Figure 1: The Collection Configuration if Collection Start = Using Trigger and One Shot Report is selected.
Last Update: Friday, May 3, 2013